The Premium Line is the right choice for manufacturers of fixed and portable gas detector needing top performances, superior stability and long expected lifetime from their sensor. Our sensor improve the common downfalls of electrochemical technology.
Measurement Ranges and Datasheets:
Ammonia
Range: 0-100 ppm - 100 nA/ppm
• Sensor NT-NH3-PL100
Range: 0-300 ppm - 40 nA/ppm
• Sensor NT-NH3-PL300
Range: 0-1000 ppm - 8 nA/ppm
• Sensor NT-NH3-PL1000
Range: 0-5000 ppm - 4 nA/ppm
• Sensor NT-NH3-PL5000
Nitrogen Dioxide
Range: 0-30 ppm - 600 nA/ppm
• Sensor NT-NO2-PL30
Range: 0-10 ppm - 1000 nA/ppm
• Sensor NT-NO2-PL10
Chlorine
Range: 0-10 ppm - 600 nA/ppm
• Sensor NT-CL2-PL10
Hydrogen Sulphide
Range: Range 0-100 ppm - 700 nA/ppm
• Sensor NT-H2S-PL100
Sulphur Dioxide
Range: 0-20 ppm - 500 nA/ppm
• Sensor NT-SO2-PL20
Carbon Monoxide
Range: 0-1000 ppm - 70 nA/ppm
• Sensor NT-CO-PL1000
SPECIAL SENSORS: Measurement Ranges and Datasheets:
Carbon Monoxide - High Temperature
Range: 0-2000 ppm - 70 nA/ppm
Temperature range: -30°C to + 60°C
• Sensor NT-CO-PL2000-HT
Carbon Monoxide - High Sensitivity
Range: 0-200 ppm - 300 nA/ppm
• Sensor NT-CO-PL200
Ethylene
Range: 0-100 ppm - 100 nA/ppmm
• Sensor NT-C2H4-PL100
Hydrogen
Range: 0-1000 ppm - 25 nA/ppm
• Sensor NT-H2-PL1000
Range: 0-40,000 ppm - 5 nA/ppm
• Sensor NT-H2-PL40000
Hydrogen Peroxide
Range: 0-300 ppm - 500 nA/ppm
• Sensor NT-H2O2-PL300
Sulphur Dioxide
Range: 0-100 ppm - 200 nA/ppm
• Sensor NT-SO2-PL100
Hydrogen Sulphide - High Temperature
Range: 0-100 ppm - 700 nA/ppm
Temperature range: -40°C to +65°C
• Sensor NT-H2S-PL100-HT
Range: 0-20 ppm - 1500 nA/ppm
Temperature range: -40°C to +65°C
• Sensor NT-H2S-PL20-HT
Chlorine
Range: 0-5 ppm - 900 nA/ppm
• Sensor NT-CL2-PL05
Nitric Oxide
Range: 0-300 ppm - 400 nA/ppm
• Sensor NT-NO-PL300
Comments:
Electrochemical sensors can be affected by other gases, resulting in a loss of sensitivity. A typical case is how the presence of Hydrogen Sulphide (H2S) can significantly affects the reading of Ammonia (NH3) sensors. In presence of H2S, the typical signal from electrochemical sensors on the market increase and follow concentration of H2S. At same time, N.E.T. sensors show a smooth negative response within a market-leading less than 10% of actual H2S concentration.
Another common downfall is how, depending on the type of sensor and the gas to be measured, the sensor is gradually consumed by the target gas. Not only this requires frequent calibration and bump-tests, but a baseline presence of gas on the environment can lead to quick depletion of the sensor itself. Our Premium Line sensors have an expected lifetime of 3 years. And our NH3 sensor again stands out for his resistance to a light presence of ammonia in the environment and his capability of recovering sensitivity after high exposures, dramatically reducing calibration and substitution frequency.
Finally, environmental factors, and temperature in particular, affect both sensitivity and baseline. Premium Line sensors maintain excellent performances throughout a very extended temperature range and our H2S-HT cell is unique on the market with an amazing -40°C +65°C.
Applications-CheckUp
> SmartCity
> Agriculture 4.0
> Industrial Air Quality Monitoring
> HVAC
Applications-Technocomm-IoT
> Environmental Radiation
> Technocomm DSaaSSupport Centre
> Privacy Notice
> Sales Support/Ask for a Quotation
> Technical Support
Contact Us
> Telephone: +55 61 99554-8964
> Mail: info@gassensorsolutions.com
> Address: SQNW 102, Brasilia, Distrito Federal, 70683-055, Brasil