Technocomm-IoT

EnviroSense

Ambient and Indoor Air Quality Monitor integrating high resolution pollution sensors

Ambient and Indoor Air Quality monitoring plays a crucial role in safeguarding public health. By systematically measuring pollutants such as Particulate Matter (PM10, PM2.5), Carbon Monoxide (CO), Nitrogen Dioxide (NO2), Sulphur Dioxide (SO2), Ozone (O3), Carbon Dioxide (CO2) and Volatile Organic Compounds (VOCs), Local/Central Government Authorities, Traffic Management Managers and Facility Managers can identify developing risk areas and implement effective mitigation strategies. Advances in sensor technology have made real-time monitoring more accessible and importantly Cost Effective.

EnviroSense - Air Quality: ☁️

Air Quality and pollution measurement sensors with LIVE data reporting

Technocomm-IoT EnviroSense multiparameter air quality monitor enables Indoor, Ambient, Local, Remote and Vehicle Mounted solutions. Combined with the CommonSense cloud platform, sensor data can be visualised, analysed and corrected using Machine Learning and Artificial Intelligence models, in real-time, from any geographical location.

Everything Everywhere.

EnviroSense

Full Specification Air Quality Monitor.

EnviroSense Standard Parameters:

• Integrated Machine Learning and AI Compensation Models
• Temperature, Humidity, Barometric Pressure sensors

• D/SaaS - Data Visualisation and Analytics

EnviroSense

Configurable Options
• Carbon Dioxide (CO2)

• Particulate Matter (PM10, PM2.5)
• Volatile Organic Compounds (VOC)
• Hydrogen Sulphide (H2S) and Methane (CH4) options

EnviroSense AI

Full configuration - Air Quality Sensors:
• Carbon Monoxide (CO)
• Sulphur Dioxide (SO2)
• Nitrogen Dioxide (NO2)
• Ozone (O3)
• Particulate Matter (PM10, PM2.5)

EnviroSense AI - Ambient Air Quality Sensor (Specifications)

AQ7ND Nitrogen Dioxide Gas Sensor

Technology: 4-electrode electrochemical
Measurement Range: 0 to 1 ppm NO2
Maximum Overload: 5 ppm NO2
Onboard Filter: to remove Ozone
Sensitivity*: 550 nA/ppm ±250 nA/ppm
Response Time (T90): < 120 seconds
Resolution*: (when using recommended electronics) 5 ppb
Baseline Offset*: <±100 nA
Repeatability*: < ±5 % of signal
Linearity**: linear
Low Detection Limit*: 5 ppb

AQ7SO2 Sulphur Dioxide Gas Sensor

Technology: 4-electrode electrochemical
Measurement Range: 0 to 1 ppm SO2
Maximum Overload: 5 ppm SO2
Onboard Filter: None
Sensitivity*: 900 nA/ppm ±300 nA/ppm
Response Time (T90): < 60 seconds
Resolution*: (when using recommended electronics) 2 ppb
Baseline Offset*: <±200 nA
Repeatability*: < ±5 % of signal
Linearity**: Linear
Low Detection Limit*: 5 ppb

AQ7CO Carbon Monoxide Gas Sensor

Technology: 4-electrode electrochemical
Measurement Range: 0 ppm to 20 ppm CO
Maximum Overload: 50 ppm CO
Onboard Filter: to remove SOx/NOx/H2S and O3
Sensitivity*: 375 nA/ppm ±125 nA/ppm
Response Time: (T90): < 60 seconds
Resolution*: (when using recommended electronics) 10 ppb
Baseline Offset*: <±200 nA
Repeatability*: < ±3 % of signal
Linearity**: Linear
Low Detection Limit*: 40 ppb

AQ7OZ Ozone Gas Sensor

Technology: 4-electrode electrochemical
Measurement Range: 0 to 1 ppm O3
Maximum Overload: 5 ppm O3
Sensitivity*: 500 nA/ppm ±200 nA/ppm
Response Time (T90): < 120 seconds
Resolution*: (when using recommended electronics) 5 ppb
Baseline Offset*: <±100 nA
Repeatability*: < ±5 % of signal
Linearity**: Linear
Low Detection Limit*: 5 ppb

* Specifications are based on measurements made with cylinder gases using a flow rate of 500 ml/min and are valid at 20°C, 50 %RH and 1013 mBar using Honeywell recommended circuitry. Performance characteristics outline the performance of sensors supplied within the first three months. Output signal can drift below the lower limit over time.

** Linear through the concentration range across the whole operational environment range.